The study protocol was approved by the NHIS Institutional Review Committee (Sa-2016-HR-02-015). Despite the approval of the use of data for research (NHIS-2017-1-019), the results of our study do not represent the official opinion of NHIS. Another requirement in comparing methods is that it is not enough to validate the technology alone. The context of the study, the study population, etc. can affect the confidence limits by 95% to some extent. The instrument, its calibration, its lowest number and processing also affect the agreement and these, as well as the validity of the technology, must be taken into account before their introduction into practice. This may seem far-fetched, but unfortunately, it`s quite common in science. Chiappini E et al., found a good match between infrared and axillary thermometry in an ideal setting and recommended their use in neonatal environments [18]. The authors found unacceptable agreement (and wider approval limits of 95%) when replicating the study with a different brand and in a different environment [19]. Fortuna EL et al.
and Sener S et al. reported similar results [20,21]. Unfortunately, few well-conducted studies could not contribute to the evidence base simply because they were inappropriately analysed [3,4]. It seems that the authors confuse the Bland-Altman plot with the Bland-Altman analysis. Simply plotting the Bland Altman plot does not mean adequate analysis. Kane CT et al. reported that 94% of the results were within the 2SD limits and reached a good agreement without discussing the magnitude of the 95% confidence limits [10]. The confusion continued and David S et al. claimed a good match between dbS and plasma samples for the same reason [11].
If the distribution is fairly normal, about 95% of the observations are between the mean±2SD. This is a statistical fact that should not be used to claim good approval. Bland and Altman identified the pitfalls and developed a method to measure agreement between two methods, showing the difference from the mean of the two methods to obtain 95% confidence limits for clinical consideration [6]. The paper was published in The Lancet in 1986 and despite the overwhelming response, the technique developed by Bland and Altman has not been sufficiently adopted and we come across papers reporting correlation/regression/ANOVA in method comparison studies. The serious problem is that the results of well-conducted studies are only invalid due to an incorrect analysis strategy. The work described a study involving 69 patients.3 Both eyes of each patient were measured with the Tonosafe Disposable Head and the Head of the Goldmann Tonometer. The Pearson correlation coefficient was used and there was a high correlation with a value of 0.94 (p<0.0001). The authors concluded that "the Tonosafe disposable prism head was accurate in the IOD measurement, even in the upper range." However, what this patient clearly showed me is that there are differences of opinion between the visual acuity diagrams of Snellen and ETDRS and that this disagreement is significant. I review the evidence and identify a doctoral thesis that measures vision in 163 patients using the ETDRS table and Snellen`s table, but expressed in logMAR.9 Although this reported a high correlation (0.88) and reasonable agreement between the graphs for subjects with good vision, the paper showed that in 56 visually impaired patients ( <6/60), the limits of the agreement were between -14.5 and 34.5 letters, with an average disagreement of 10 ETDRS letters. The thesis provided Bland-Altman plots that very clearly illustrated the disagreement with poor visual acuity and clearly indicated that in patients with visual impairment, the method of recording visual acuity should be taken into account.
Background: Precise values are essential in medicine. An important parameter for determining the quality of a medical device is compliance with a gold standard. Various statistical methods were used to test the match. Some of these methods have proven to be inappropriate. This can lead to misleading conclusions about the validity of an instrument. The Bland-Altman method is the most popular method given the many quotes in the article that suggests this method. However, the number of citations does not necessarily mean that this method has been used in chord research. No previous studies have been conducted to investigate this.
This is the first systematic review to identify statistical methods used to test the compliance of medical devices. The proportion of different statistical methods found in this review will also reflect the proportion of medical devices validated with these particular methods in current clinical practice. Other methods of evaluating associations, such as the t-test/analysis of variance (ANOVA), are also not suitable for the analysis of conformity studies for the same reasons. Duran R et al. used ANOVA to compare 3 methods to measure the temperature of low birth weight preterm infants [4]. He made a good deal because there was no statistically significant difference between the average forehead and armpit temperatures. Given the reporting trends in patients, more accurate diagnoses and treatments are needed to achieve a good prognosis for those who report the disease too little. Estimating accurate descriptive statistics at the national level is essential for defining an effective and equitable health policy. Our study identified different levels of agreement between self-reported data and claims data by disease type, diagnosis period and patient characteristics using a large national population-based dataset. Our study also identified more patient characteristics associated with information bias than previous studies. However, there were several limitations to our research. First, the accuracy of diagnoses may be affected by the expense reimbursement system, which may result in updated claim data [24].
This means that claims data may not be reliable and questionnaire data and disclosure data may be inaccurate. However, we applied different scanning methods to the loss data to overcome this limitation. Second, we did not take into account the effects of the drugs. Although medication was not a major concern in this study, there was a possible interaction between reporting a diagnosed disease and history of drug treatment. Conclusion: If the research question is about differentiating people, the reliability parameters are the most appropriate. However, when it comes to measuring the change in health status, which is often the case in clinical practice, agree parameters are preferred. Methods and results: Using the example of an interracter study in which various physiotherapists measure the range of motion of the arm in patients with shoulder pain, the differences and relationships between the reliability and agreement parameters for continuous variables are illustrated. The overall correspondence, sensitivity, specificity and kappa values are shown in Table 2. Claim data based on primary diagnostic codes up to 1 year before the self-reported questionnaire showed a higher match with questionnaire data than claim data based on primary and secondary diagnostic codes up to 5 years before self-reported data.
Specificity was highest when questionnaire data were compared with claims data based on primary and secondary diagnostic codes up to 5 years prior to self-reported data. Comparing data based on primary diagnostic codes up to 1 year before self-reported data, overall match, sensitivity, specificity and kappa values for the 6 diseases ranged from 93.2 to 98.8%, 26.2 to 84.3%, 95.7 to 99.6% and 0.09 to 0.78% respectively. Comparing data based on primary and secondary diagnostic codes up to 5 years prior to self-reported data, the overall compliance, sensitivity, specificity and kappa values for the 6 diseases ranged from 67.4 to 98.0%, 10.7 to 66.3%, 99.0 and 99.8% and 0.13 to 0.73, respectively. In 2014, a total of 13,281,550 people participated in health check-ups. .